We can also see that the disk in Slot07 was recently swapped, and that Slot08 does not contain a disk and its locate LED is activated. SES provides a mechanism to query information from the enclosure, including temperature, fan speed, and status reveryplay of power supplies. Many backplanes include support for SCSI Enclosure Services (SES).
When it comes to long-term data storage, there are several strategies and media types that Redditors recommend. It refreshes the disks SMART information every 5 min. ZFS and Btrfs both aim to modernize storage by combining filesystems and volume management, but… Monitoring and maintaining your storage media is one of the most important parts of keeping your data safe.

Top downloads Remote control for Windows

Other interfaces for remote storage include iSCSI, Fiber-Channel, Infiniband, RoCE, and others, but those specialized solutions are beyond the scope of this article. Serial Attached SCSI (SAS) is the most common interface for enterprise storage, first appearing in 2004. Serial ATA (SATA) is the familiar interface used for non-enterprise storage, and is an extension of the original ATA interface dating from the 1980s. In this article we will discuss some strategies and tools to make managing disk arrays on FreeBSD (and related platforms like TrueNAS Core) much easier. It may be what you want is to enable HDD standby, which will “spin down” the drives when not in use

User reviews about AnyDesk

Below we will discuss exactly how to do this with FreeBSD’s sesutil or the management tools for your HBA. Though a truism, it bears emphasizing that with a little planning, management and maintenance of storage systems can be made easier and safer. The total throughput possible from the connected disks is still limited by the number of lanes available, but this is likely the best approach in systems with more than a dozen disks.
I moved the system dataset to the boot pool. I don’t move any data, no apps are running, this is a vanilla Scale install so far, yet the HDD is in constant work. 1 SSD to boot and 1 HDD to store data. Agree, I have used SeaChest with good results for this same issue on scale plus drive cache. If you do it on a live pool, I’d back up your data first.
Most Seagate disks have configurable Extended Power Conditions (EPC) settings that include timers for how long the disk needs to stay idle before entering various low-power modes. Disk vendors typically provide their own vendor-specific ways to do persistent configuration of power management settings, so it’s worth trying to use those instead so the desired configuration doesn’t depend on the host system applying it, instead being configured in the drive (but in some cases it might be desirable to have the host configure that!). To prevent parking the heads at all a value greater than 128 may do the job (254 is a common choice, as the highest-power setting available), but it’s possible that some disks won’t behave this way because the ATA specification refers only to spinning down the disk and does not specify anything about parking heads. Typical SAS connectors support up to 4 drives per “lane”, but with an expander up to 255 devices are possible. An eight lane controller can only directly attach to 8 disks, requiring more controllers (consuming additional PCI-E slots) to connect more drives. This has long been the interface bus used by most home users to connect their hard drives, and is supported by nearly every motherboard.

Connect to a computer or mobile device remotely, whether it’s across town or halfway around the world.

Direct Attached deployments require a bit more hardware and cabling. The NVMe interface is also extensible to allow operating over the network (where it is known as NVMe Over Fabric or NVMe-oF). NVMe on the other hand, supports multiple queues (often 64 queues, but the official specification allows for up to 65,536 queues) allowing for many commands to be run concurrently. While both SATA and SAS allow multiple commands to be issued at once to the device, these commands cannot actually be executed concurrently—instead, they are queued for sequential operation.

How do I transfer files with AnyDesk?

The APM specification dating from 1992 includes some controls for hard drives, allowing a host system to specify the desired performance level of a disk and whether standby is permitted by sending commands to a disk. In addition to the above query types, SES also supports a number of commands, including activating the “locate” and “fault” LEDs if present, and the ability to individually power off drives. The first step is to map out the relationship between the physical chassis where the disks reside, and the logical devices enumerated by the operating system.
I moved my Scale server into the next room, laundry room, just so it’s out of sight. Replacing the drive is financially out of the question. I’m looking for a software solution, if possible, to make the HDD idling for most of the time when there is no load. Yeah, it’s not helping, thanks. Although it’s empty, so this is probably not the source of the constant HDD noise.
SATA disks plugged directly into the motherboard use an interface called AHCI which does not provide much in the way of advanced management features. For smaller numbers of drives, and for most home systems, the most common way the disks are attached is to the SATA controllers built into the motherboard. Non-Volatile Memory Express (NVMe) is a newer storage interface that is becoming very popular for flash storage devices. Just download the executable file on both devices and run it to open the tool. At a glance, changing idle3 and EPC settings seems to have done the job nicely; here is the same graph of head park rates per disk as before, but on a smaller timescale that makes individual head parks visible. Seagate provide a “Seachest” collection of tools for manipulating their drives, but rather more usefully to users of non-Windows operating systems like Linux they also offer an open-source openSeaChest.

Unlock the Power of OpenZFS, Linux, and FreeBSD with Klara’s Open Source Development Experts

The timer values specified are in milliseconds, so this example will park the disk heads after 30 minutes of inactivity. If we wanted to allow the disk to still park its heads but at minimum frequency, setting the APM value to 7Fh (hdparm -B 127) seems to be the correct choice. Of the three disks that I decided need some attention, I have one Western Digital disk and two Seagate ones.
In this case, there are at least two disks that I probably need to configure, since /dev/sde seems to be parking as often as about every 4 minutes (0.004 Hz) and /dev/sdc is only parking slightly less often. The smartmon_load_cycle_count_value metric seems like it would be the right one to query, but that actually expresses a percentage value (0-100) representing how many load cycles remain in the specified lifetime- on reaching 0 the disk has done a very large number of load cycles. It does support reading arbitrary metrics from text files written by other programs with its textfile collector however, which is fairly easy to integrate with arbitrary other tools. These communities are filled with knowledgeable individuals who can offer more personalized advice and help you navigate the complexities of long-term data storage.

  • I gave up and just built a Windows Storage Space with tiering and the drives are now effectively silent.
  • With modern, especially Enterprise grade hard drives being able to have hundreds of thousands of head park operations in their service life, is this really an isssue?
  • Each SAS Expander will present as a new /dev/ses# device, so your system may have more than one.
  • The total throughput possible from the connected disks is still limited by the number of lanes available, but this is likely the best approach in systems with more than a dozen disks.
  • Somewhat more useful for monitoring is the smartmon_load_cycle_count_raw_value, which provides the actual number of load cycles that have been done.
  • Many backplanes include support for SCSI Enclosure Services (SES).

For ZFS users, automating fault responses with tools like ZED (ZFS Event Daemon) can simplify disk replacement and minimize downtime. Configuring your system to notify you when a disk has errors, or when the filesystem reports a degraded device, will ensure your system gets prompt attention when something goes wrong. Experienced enterprise storage managers also keep extensive notes including the model number, SKU and/or URL for reordering, purchase order information, warranty end date, warranty URL, and any other useful information about each drive. While the operating system typically provides device aliases based on the disk’s serial number, WWN, or some other static identifier, this does not provide all of the information you might want.

  • Typical SAS connectors support up to 4 drives per “lane”, but with an expander up to 255 devices are possible.
  • For drives made by Western Digital, the inactivity timer for parking the heads is called the idle3 timer.
  • These communities are filled with knowledgeable individuals who can offer more personalized advice and help you navigate the complexities of long-term data storage.
  • You can avoid any uncertainty by enabling the “locate” or “fault” LED for the drive you mean to replace.
  • To prevent parking more often that is useful (for a server, usually that choice would be “very rarely”), there are a couple ways to do it and which apply will depend on what the hard drive vendor’s firmware supports.
  • It may be what you want is to enable HDD standby, which will “spin down” the drives when not in use
  • This has long been the interface bus used by most home users to connect their hard drives, and is supported by nearly every motherboard.

This will activate the fault LED for element 9 (Slot 08) on the first SES device. You can avoid any uncertainty by enabling the “locate” or “fault” LED for the drive you mean to replace. This example creates a new GPT partition scheme on da36, creates a 4 GiB swap partition aligned to 1 MiB boundaries, and then adds a ZFS partition with the label e3s01-ZGY0XH87 using the remainder of the space on the disk.
Unfortunately, APM settings don’t persist between power cycles so if we wanted to change disk settings with APM they would need to be reapplied on every boot. Advanced power management levels80h and higher do not permit the device to spin down to save power. For example, a device may implement one power management method from 80h to A0h and a higherperformance, higher power consumption method from level A1h to FEh. To prevent parking more often that is useful (for a server, usually that choice would be “very rarely”), there are a couple ways to do it and which apply will depend on what the hard drive vendor’s firmware supports. With the SMART metrics captured by Prometheus, it’s fairly easy to write a query that will show how often a given disk is parking its heads. Since I use Prometheus to capture information on the server’s operation however, I can use that to monitor that my hard drives are doing well.
If your system has multipath SAS, each disk will be present more than once, and you should use the gmultipathcommand to deduplicate your disks and for labeling as well. FreeBSD supports a number of different ways to label the disk, depending on your use case. The map command displays all of the SES devices and each element (this is the nomenclature in SES) connected to them. Of course, all of this chassis management technology isn’t very effective without tools to make it usable. It also provides information about each slot in the enclosure (even if empty), including a flag to indicate if the device has recently been swapped.

AnyDesk for Windows

Unnamed devices can be specified by their specific SES device and element number. This greatly reduces the chance of getting it wrong when you (or the datacenter technician) physically pulls the disk. You can also reboot, and GEOM will pick up the multipath when it first tastes the disks during boot.